Performance Parameters of the Fully Automatic Gravimetric Vapor Adsorption Instrument

Index Parameter Description
Sensitivity / Sample Size 1 µg / 10 g, up to 5–10 times better than similar products, significantly improving accuracy.
Simultaneous Analysis of Sample Size Available options: 2, 4, or 8 samples; multi-station analysis improves efficiency greatly.
Test Gas Type Water vapor, organic vapor, and various gases (customized for strong acid gases).
Support for Blank Position Synchronization Test Supports background subtraction and buoyancy deduction, reducing system errors and enhancing test accuracy.
Vacuum Degassing Temperature Control Multi-stage temperature programming prevents overheating, protecting samples and avoiding sample loss.
Vacuum Degassing Temperature Range From room temperature to 400°C.
Full System Anti-Condensation Constant Temperature Controlled from room temperature to 60°C, preventing condensation throughout the system.
Analysis Test Temperature Ranging from -180°C to 50°C.
Segmented Pressure Measurement Equipped with original imported capacitive film pressure sensors, dual sensor configuration. Segmented testing: 0–10 torr and 0–1000 torr. Reading accuracy ≤ 0.15%, offering the highest precision available.
Segmented Pressure Sensor Configuration Provides higher accuracy for vapor-based adsorbates with low saturated vapor pressure at normal temperatures. Improves test accuracy by more than two orders of magnitude compared to single-pressure sensors.
Vacuum Degree Less than 0.001 torr; optional molecular pump can reach up to 10⁻⁶ torr.
Dual Mode Buoyancy Correction Mode 1: Buoyancy calculation mode. Mode 2: Background subtraction curve mode.
Steam Concentration Control Range 0.01% to 98% P/Pâ‚€. Uses advanced "static evaporation" method to achieve a wider range of steam partial pressure compared to "carrier gas mixing."
"Humidity/Partial Pressure" Accuracy Better than 0.001 torr. Direct absolute pressure testing and saturated vapor pressure (Pâ‚€) measurement ensure over 10 times higher accuracy than hygrometers.
Real-Time Saturated Vapor Pressure Test Measures saturated vapor pressure in real time, ensuring extremely high relative pressure accuracy. Significantly improves accuracy compared to indirect methods like temperature conversion or table lookup.
Steam Trap Cold Trap Includes a liquid nitrogen cold trap to prevent steam from entering the vacuum pump, protecting the pump oil. Captures high-boiling-point adsorbents, essential for steam adsorption analysis.
Static Adsorption Process Uses the most advanced vacuum static pure steam adsorption process, eliminating the need for carrier gas and minimizing dynamic gas interference.
Distillation Purification System Features an advanced automatic distillation purification system that ensures high-purity steam sources, improving test accuracy by reducing reagent purity requirements.
Anti-Condensation Full Temperature Control All components, including the adsorption chamber, reference chamber, valves, and gas lines, are maintained at constant temperature to eliminate cold spots. Uses high-vacuum air control valves to reduce heating issues and enhance thermal stability.
Intelligent Automatic Calibration The microbalance automatically calibrates before each test, ensuring consistent accuracy and eliminating manual calibration steps.
Pneumatic System Features a modular air circuit system with integrated control valves, minimizing leakage points. Uses 316L stainless steel high-vacuum valves, achieving an air leakage rate below 10⁻⁸ torr·m³/s. Sealing performance is more than five times better than standard systems, matching high-end imported instruments.
Oil and Corrosion Resistance All pipelines and valves are sealed with oil-resistant and corrosion-resistant materials. Special valves resist oil and organic vapor corrosion, making the system suitable for water vapor, organic vapor, and petroleum product analysis.
Pipeline Diameter Larger diameter is essential for achieving high vacuum. Large-diameter valves and pipes at degassing and test positions maximize the ultimate vacuum of the vacuum pump.
Quartz Wire Insulation Seal Uses advanced quartz wire insulation sealing technology for pressure and temperature sensors, offering low leakage, long-term stability, and resistance to aging.
Intelligent Self-Test Automatically detects and evaluates the instrument’s airtightness, ensuring reliable operation and performance.
Automatic Email Notification Notifies users via email when tests are completed or if unexpected events occur, even during business trips, allowing real-time monitoring of the instrument's status and results.
Other Features Clear graphical interface with full hardware control on the software. Detailed logs accurate to the second, ensuring reliable operation and after-sales support. Live voice prompts for each test step. Supports multi-language modules customizable for editing. Global procurement ensures all key components are imported. Dimensions: H110cm × W100cm × L70cm, Weight: 200kg.

Composite Insulators

The Composite Insulator are made of glassfiber epoxy core rod, silicone rubber shed and metal fittings.
The silicon rubber shed adopt the whole packing pressure technique, can solve the key problem – interface electric spark puncture, which would affect the reliability of composite insulator.
Connection of the glassfiber rod and metal fittings adopts the pressure welding technique of the international advanced level, and have the full automatic sound wave detection of defects system, high intension, beautiful outline, small volume, light weight, and the metal fitting of galvanization can corrosion prevention and exchange used with porcelain insulator.


Composite Insulators,Insulation Resistance,Transmission Lines Insulator,Line Post Type Insulator

Jilin Nengxing Electrical Equipment Co. Ltd. , https://www.nengxingelectric.com