TCL-color TV common faults in 65 cases - android - Phones Developers

Brand AVX TPSE226M035R0125 Low impedance tantalum capacitor AVX 22
Filter 18.432M
Probe current voltage pin 420*4450 head diameter 5.0 over current current and voltage pin

Example 1
Model: 2501C, 2568C, 2536C, 2511C
Fault phenomenon: automatic search fails, vertical bright line
Analysis and maintenance: Open the internal I2C menu to record data, replace with a new 24C04 chip, then rewrite it. A vertical bright line is usually caused by a burned L413 inductor. After repair welding, check if R411 (680Ω) has deteriorated and replace it with a 1K resistor. Example 2
Model: 2901A
Fault phenomenon: color cast after one year of use
Analysis and maintenance: Replace the picture tube. If the TV cannot automatically search for channels, try replacing the 24C04 chip. If there's image distortion or enlargement, it may be due to a blown L414 inductor. Replacing it with L801 (352) might not fully resolve the issue, requiring further adjustment. Example 3
Model: 2909A
Fault phenomenon: remote control range is short, no auto search, vertical line, and "three no" issue.
Maintenance: Check if C070 was omitted during factory installation. Install a 47μF/16V capacitor. Replace 24C04, repair L413, and check R411. Also, check TA8427K (pin 6) power supply diode D431 (FR105). If it's open, replace it with FR104. Example 4
Model: 2966G
Fault phenomenon: automatic shutdown, stuck switch, red screen, missing L segment programs, automatic search always shows "1", and "sizzling" sound.
Analysis and maintenance: Change R872 from 4.7/1W to 47K/W. Remove the switch mold, scrape the blade hole, and reinsert the spring. Replace 24C04 if necessary. Check the high-frequency head. For the program number issue, check the connection between TB1240 (pin 1) and TCLM06V3 (pin 13). If the copper foil is broken, repair it. Also, check for loose L413 inductor core and secure it with 502 glue. Example 5
Model: 2910
Fault phenomenon: occasional horizontal line
Maintenance: C302 was incorrectly installed at the factory. It should be 100μF/35V instead of 100μF/16V. This affects the TDA8351(3) pin voltage, which should be +18V. Example 6
Model: 2911D, 2911DZ, 2980G
Fault phenomenon: repeated tube burning, image shift, vertical dark band, no characters.
Maintenance: Replace C416 and C417 if performance is poor. Check +B voltage and ensure no short circuit. Replace BU4508AX if needed. D8408 (8V2) may also need replacement. Example 7
Model: 2939DR
Fault phenomenon: reduced grating circumference and pincushion distortion
Maintenance: The external R232 (39K/1/2W) on OM8838P (pin 52) is deteriorated. Replace it without increasing resistance. Example 8
Model: 2952B, C2533, 2502, 2909B
Fault phenomenon: jitter, loud boot sound, color cast, pincushion distortion, large amplitude.
Maintenance: Replace 24C04 if the internal program is corrupted. Use an experienced technician to handle the replacement. Example 9
Model: 2980G, 2988D
Fault phenomenon: two fuses blow within a month
Maintenance: If the fuse burns again after replacement, check the degaussing coil socket. A set of 20Ω three-terminal resistors is needed to reduce the starting current. Example 10
Model: 2975D
Fault phenomenon: trapezoidal distortion, normal sound
Maintenance: R232 (39K) on OM8838P (pin 52) has deteriorated to 50K. Replace it with a new 39K resistor. Example 11
Model: 2977E, 2966GL, AT2956, 2510G
Fault phenomenon: sudden "three no" condition and burning smell
Maintenance: R802 (S237-479·NTC417) is burned out. Replace it with a 7W/3R3 cement resistor and repair the PCB. Example 12
Model: 3498GH
Fault phenomenon: blue screen, no signal, "three no," and repeated tube burning
Maintenance: Check VT voltage on R440 (15K/2W). Replace with 12K. After replacing the tube (D1880 or D2553), replace C2482 with C4544 as it gets too hot. Example 13
Model: 9629B, 9625BZ, 2968SZ, 3438R, 2969
Fault phenomenon: pincushion distortion
Maintenance: D421 or FR104 is damaged. Replace it. Example 14
Models: 9614C, 1419, 9621B, 9621C, 9621D, 1701, 2128, 2129, 2129S, 2166
Fault phenomenon: "three no," switch tube burning, raster sometimes missing or horizontal line
Maintenance: D805 (18V voltage regulator) may be shorted. Check R808, R811, R812, R813 for open circuits. IC602’s 7809 pin may be loose. Example 15
Model: 2568, 2968SI, 2969, 2969A, 9629B, 2968P
Fault phenomenon: boot indicator on, no display
Maintenance: The main power output inductor is soldered. Resolder it carefully.