66kv~500kv High Voltage XLPE Insulated Power Electric Cable

Model NO.: YJLW02
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, RoHS
Model: Yjlw02-Z Yjlw03-Z Yjq02-Z Ujq03-Z
Size(mm2): ......95.120 185, 240,300,400, 500, 630,800,1000
Produceing Experience: 15 Years
OEM: Yes
Specification: SGS CCC IEC
Origin: Henan
HS Code: 8544601300
Model NO.: YJLW02
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, RoHS
Model: Yjlw02-Z Yjlw03-Z Yjq02-Z Ujq03-Z
Size(mm2): ......95.120 185, 240,300,400, 500, 630,800,1000
Produceing Experience: 15 Years
OEM: Yes
Specification: SGS CCC IEC
Origin: Henan
HS Code: 8544601300
66kV 110kV 132kV 220kV High Voltage XLPE Insulated Power Cable

1.Cable Description:
Single core,Copper conductor, XLPE insulation,Corrugated Aluminum sheath, or lead alloy sheath, or Copper wire Screen,PVC or PE Outer sheath power cable


2.Cable property:

1)The maximum rated working temperature of conductor is 90°C, and the maximum temperature is less than 250°C when short circuit occurs(no more than 5 seconds
2)
Allowable maximum lateral pressure is 5KN/m.
3)
Allowable maximum traction strength of aluminum conductor is 40N/mm2.
4)Cable laying temperature is not less than 0°C.
5)The minimum bending radius is no less than 20D.

          (D---represents actual outer diameter of cable)

3.Type and Application:

66kv~500kv High Voltage XLPE Insulated Power Electric Cable

4.Structure Drawing
66kv~500kv High Voltage XLPE Insulated Power Electric Cable



5.Size range we produce:
66kv~500kv High Voltage XLPE Insulated Power Electric Cable
6.Packing:
   Wooden Drum, Steel Wooden Drum, All Steel Drum for very heavy cable
66kV 110kV 132kV 220kV High Voltage XLPE Insulated Power Cable

1.Cable Description:
Single core,Copper conductor, XLPE insulation,Corrugated Aluminum sheath, or lead alloy sheath, or Copper wire Screen,PVC or PE Outer sheath power cable


2.Cable property:

1)The maximum rated working temperature of conductor is 90°C, and the maximum temperature is less than 250°C when short circuit occurs(no more than 5 seconds
2)
Allowable maximum lateral pressure is 5KN/m.
3)
Allowable maximum traction strength of aluminum conductor is 40N/mm2.
4)Cable laying temperature is not less than 0°C.
5)The minimum bending radius is no less than 20D.

          (D---represents actual outer diameter of cable)

3.Type and Application:

66kv~500kv High Voltage XLPE Insulated Power Electric Cable

4.Structure Drawing
66kv~500kv High Voltage XLPE Insulated Power Electric Cable



5.Size range we produce:
66kv~500kv High Voltage XLPE Insulated Power Electric Cable
6.Packing:
   Wooden Drum, Steel Wooden Drum, All Steel Drum for very heavy cable

The Shielded Cable is a cable that is resistant to external electromagnetic interference formed by a transmission cable plus a shield.

Most of the shielding layers of such cables are woven into a mesh metal wire or a metal film, and there are many different ways of single shielding and multiple shielding. Single shielding refers to a single shielding mesh or shielding film in which one or more wires can be wrapped. The multi-shielding method is a plurality of shielding nets, and the shielding films are all in one cable. Some are used to isolate electromagnetic interference between wires, and some are double-layer shields used to enhance the shielding effect. The mechanism of the shielding is to ground the shield to isolate the externally induced inductive voltage of the conductor.


Shielded Cable

Shielded Cable,Shielded Usb Cable,Double Shielded Ethernet Cable,Control Signal Cable

Jiangsu QiSheng Cable Co., Ltd. , http://www.shuaihe-cable.com